<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>17016</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: is not responding
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The exposure head is not responding. The exposure head to backplane (EH-BP) cable should be checked.
The exposure head's digital board should also be checked (parameters stored in EEPROM must be restored
if the board is swapped).  Check that the board has +5V.  The MPE may also be faulty.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reboot the platesetter.  Even if this error does not happen again, please report it to Creo Service as the
Platesetter may need servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty EH-BP (exposure head to backplane) cable
</Cause>
<Cause>
Exposure head digital board faulty or not mounted correctly
</Cause>
<Cause>
Faulty MPE
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:33 2008 PST
</Updated>
<Links>
</Links>
</Error>